高频热合机保养与维护
保养与维护
Maintenance and maintenance
1. 定期检查滤水器;
Check the water filter regularly.
2. 如机台有尘埃,用于燥压缩空气小心吹干净机台,但必需关闭总电源;
2. If there is dust in the machine table, it is used for drying compressed air to carefully blow off the machine, but the total power supply must be turned off.
故障:在检查前,一定要关闭总电源,因机台里面有几千伏至上万伏电压。
Failure: before checking, must turn off the total power supply, because there are several thousand volts to tens of thousands of volts in the machine.
现象1:常见红灯(过载灯)
Phenomenon 1: common red light (overload light)
原 因:
The reason:
A) 下模绝缘物损坏;
A) the lower die insulation is damaged;
B) 工作物,振动筒或上下模有脏物、尘埃、水份需清理;
B) working objects, the vibrating cylinder or upper and lower mould has dirt, dust and moisture to be cleaned;
C) 上下模水平位不良;
C) poor horizontal level;
D) 上下模没有绝缘物,而直接碰在一起;
D) there is no insulation in the upper and lower modes, and directly touching them;
E) 输入电源太高;
E) the input power is too high;
F) 真空管损坏或松脱;
F) the vacuum tube is damaged or loose;
G) 过电源保护电子板损坏,过电流保护板即有三个总电器的那一块;
G) the power protection electronic board is damaged, the current protection plate is the one with three total appliances;
H) 同调器太大,输出太高;
H) the modulator is too large and the output is too high;
I) 工作物太大,超出同机台的额定输出;
I) the work item is too large, exceeding the rated output of the same machine;