保养与维护 Maintenance and maintenance 1. 定期检查滤水器; Check the water filter regularly. 2. 如机台有尘埃,用于燥压缩空气小心吹干净机台,但必需关闭总电源; 2. If there is dust in the machine table, it is used for drying compressed air to carefully blow off the machine, but the total power supply must be turned off. 故障:在检查前,一定要关闭总电源,因机台里面有几千伏至上万伏电压。 Failure: before checking, must turn off the total power supply, because there are several thousand volts to tens of thousands of volts in the machine. 现象1:常见红灯(过载灯) Phenomenon 1: common red light (overload light) 原 因: The reason: A) 下模绝缘物损坏; A) the lower die insulation is damaged; B) 工作物,振动筒或上下模有脏物、尘埃、水份需清理; B) working objects, the vibrating cylinder or upper and lower mould has dirt, dust and moisture to be cleaned; C) 上下模水平位不良; C) poor horizontal level; D) 上下模没有绝缘物,而直接碰在一起; D) there is no insulation in the upper and lower modes, and directly touching them; E) 输入电源太高; E) the input power is too high; F) 真空管损坏或松脱; F) the vacuum tube is damaged or loose; G) 过电源保护电子板损坏,过电流保护板即有三个总电器的那一块; G) the power protection electronic board is damaged, the current protection plate is the one with three total appliances; H) 同调器太大,输出太高; H) the modulator is too large and the output is too high; I) 工作物太大,超出同机台的额定输出; I) the work item is too large, exceeding the rated output of the same machine; |